Hawk 6000

Description

CB Part #: CB-8520

  • Lower fuel cost
  • Parallel positioning, full metering or single poin
  • Cutting edge combustion control logic in a user-friendly environment
  • Full configured including preset combustion parameters for easy commissioning from HMI
  • 10″ color touch-screen interface, PLC based

    The Hawk 6000 package includes the same features and flexibility of the Hawk 5000, but engineered for total integration with the Cleaver-Brooks Configurable Watertube (CBCW) requiring single point positioning, parallel positioning or fully metered controls.

Product Overview:

  • Fireye (CB120E) based integrated burner management system.
  • Allen-Bradley Panelview Plus 10” color touch screen HMI for setup, monitoring and data acquisition using latest display ergonomics.
  • Various screen size option with capabilities to mimic PLC screens to PC environment. Pre-configured and fully tested at our facility before shipment.
  • Commissioning tuning done from the HMI including our new fully metered fast setup procedure. ISA (International Society for Automation) standard used for symbol labeling of the HMI
  • and documents.
  • Nema 12 Industrial grade enclosure (Nema 4 or 4X in option) wall-mounted or free-standing. NFPA 85 – 2011 or CSA B149.3 compliance
  • Professionally assembled and pre-wired internal components compliant with UL/CSA Standards for industrial control enclosure.
  • Supplied with a complete set of documents meeting the industry standards.
  • After sale support by factory control system engineer and/or Field service technician.
  • Training program available.
  • Economizer monitoring and control

    This complete boiler control system meets institutional and industrial market specifications for North America standards. A simple and user-friendly interface provides access to the latest combustion control logics; benefiting from years of proven engineering experience developed for the petrochemical and utility markets. All commissioning can be performed through the HMI. Inputs and outputs have been pre-characterized to obtain linear response at all boiler loads and avoid tedious f(x) entries.

    The result is unsurpassed performance when coupled with a C-B industrial burner system. All Hawk 6000 systems include Ethernet communication, first out and alarm history, local or remote steam demand and much more.

Applications:

  • Process Steam
  • Industrial Process
  • Building Heat
  • Sterilization
  • Healthcare
  • District Heats
  • Food and Beverage
  • Chemical
  • Electronics
  • Rental Equipment
  • Pulp and Paper
  • Rotary Dryers

Contact us for any part inquiry

Main Office

Address: 2 Hudson Street, Sleepy Hollow, NY 10591

Tel: +(914) 332-0088

Fax: +(914) 332-9463

Email: info@mpnboilers.com

Website: mpnboilers.com

Long Island Office

Address: 1363 Lincoln Avenue, Unit 3, Holbrook, NY 11741

Tel: +(631) 253-2300

Fax: +(631) 253-0166

 

New York City Office

Address: 1501 Broadway, 12th Floor
New York, NY 10036

Tel: +(631) 847-2601

 

24-Hour Emergency Service

Tel: +(914) 332-0099

Quick Contact

FOR EMERGENCY SERVICE DIAL (914) 332-0099 24 HOURS A DAY – 7 DAYS A WEEK – 365 DAYS A YEAR